Curtain machine and actuator control
|
|
|
|
Home > HORTICULTURE / GREENHOUSE > Horticultural/Greenhouse Product Line > Environmental Controls > Curtain Machine Control > Curtain machine and actuator control |
|
 |
Curtain machine and actuator control MODEL: NVC
|
|
Additional Details
|
|
NVC
• Two relay stage outputs (open/close).
• One alarm relay output.
• Adjustable temperature set-point.
• Adjustable temperature differential.
• Adjustable open/close durations (1 to 900 seconds).
• Adjustable idle duration (1 to 900 seconds).
• Adjustable high/low temperature alert settings.
• Manual override to open/close curtains.
• Lock mode to prevent setting changes.
• Curtain status LEDs.
• Four-digit LED display.
• Fahrenheit and Celsius display.
• Error code display for troubleshooting.
• Overload protection fuse.
• 30-foot temperature probe, extendable to 500 feet.
Input:
115/230 VAC, 50/60 Hz.
Open / Close Relays: 6 FLA
|
|
|
|
|